Trolmaster Hydro-X Dual Condition Adaptor DCC-1

Trolmaster Hydro-X Dual Condition Adaptor DCC-1

Trolmaster Hydro-X Dual Condition Adaptor DCC-1

$130.00  
The TrolMaster DCC-1 provides a simple solution to control a single device, with more than...
Brand: Trolmaster
Product type: Environmental
SKU: J4245
Availability:

Pre Order

For an ETA please call us on (03) 5940 9047 or email us here.
QUALITY PRODUCTS

For All Your Hydroponics Needs

AUSTRALIA-WIDE DELIVERY

Or Pick-Up from Our Store

PAYMENT OPTIONS

Pay In-Store or Buy Online

CUSTOMER SUPPORT

Contact Us Via Phone or Email

The TrolMaster DCC-1 provides a simple solution to control a single device, with more than one condition. For example, people like to turn on their exhaust fans when either temp or humidity is too high; shut off CO2 when turn on exhaust fans. There are many other examples where two conditions can be either combined or split. 

The DCC-1 is designed to be used in combination with one of TrolMaster’s plug-in style module. (DSC-1, DSH-1/2, DST-1/2, DSP-1/2, DSV-1 and DSD-1). 

Once connected to the plug-in module using the RJ12 cable built-into the DCC-1, the DCC-1 will act in concert with that plug-in module to control whatever device is connected to the plug-in module. 

The DCC-1 can also be set to work in two distinct ways using the “Interlock” function.

INTERLOCK OFF: When the DCC-1 interlock is set to be off, EITHER condition that are associated with that pair of modules that are being used together can be activated individually for the device to be activated. (modules used in “parallel”)

Examples from above for interlock OFF would be:  

- Turn on an exhaust fan to reduce temp or humidity.

- Turn on an exhaust fan at night using a recycling timer OR when Humidity is too high

INTERLOCK ON: When the DCC-1 Interlock is selected to be on, BOTH conditions that are associated with that pair of modules that are being used together must be activated TOGETHER in order for the device to be activated. (modules used in “series”)

Examples from above for interlock ON would be:  

- Shut off a CO2 device when an exhaust fan is running

- Shut off lights if the temperature gets too warm within the area